A/D Converters
AD converters have an offset. When the voltage U = 0V is applied, the ADC generally does not output the number 0. The offset can be determined for individual ADCs and then subtracted from the result. But it varies from specimen to specimen and it is not constant. In addition, the offset varies with temperature. That is why it is only possible to compensate the offset at all times with a great deal of effort. Expensive ADCs have very low offset values.
The slope of the characteristic of an ADC is determined by the number of bits and the reference voltage. The number of bits does not change. The reference voltage is inaccurate. The initial value of the reference voltage and the change in the reference voltage with temperature are important parameters when choosing the right ADC for an application. If the ADC can work with an external reference voltage, this parameter is specified independently of the ADC by a separate IC. Often, better external references are available than the internal references built into the ADC.
Note how much current a voltage reference can deliver. You may have to decouple the reference voltage with the help of a buffer. The offset voltage of the buffer is a particular problem here.
The characteristic of ADCs is non-linear. This is described in chapter 2 of this article of the German Wikipedia.
On ADC errors, please also read this PDF document (in German) from page 11.