Calculating the Losses
Static and dynamic losses occur in switches. The static losses depend on the component. With IGBTs and diodes, a voltage is present across the switch even when it is closed. To determine the static losses, this voltage is multiplied by the load current and the duty cycle. The duty cycle determines how long the switch conducts the current relative to the PWM period.
MOSFETs have an on-resistance. The static losses are calculated from the on-resistance, the load current and the duty cycle. The following applies:
Every switchover of the midpoint voltage causes dynamic losses in the switches. The more often switching takes place, the more often the losses occur. The losses of one switching operation are therefore multiplied by the switching frequency. Because switches are switched on and off once each during a PWM period, we can add the turn-on and turn-off losses for the mean power loss. We take these values from the data sheet. They depend on the switching voltage, the switching current and the duration of the current and voltage change. The following applies:
We use energies instead of powers to calculate the switching operations. Frequency has the unit 1/s. Energy is defined as the product of power and time. The product of frequency and energy is therefore a power.
Optimising the losses
The dynamic losses increase when switching takes place frequently. This is the case at a high switching frequency. However, we need the high switching frequency to achieve a low current ripple with small inductors and capacitors.
These are classic optimisation problems. If we change the switching frequency, we make one parameter worse and the other better. There is no single right solution here; it has to be found anew for each system.
Example
If the switch is operated at a switching frequency of 10kHz, it closes 10000 times per second. It also opens 10000 times per second. So it is switched 20000 times. With this we can calculate the dynamic power loss. All we still need is the energy for switching on and off. We calculate the losses of one switch of the half bridge:
The static power loss in the switch depends on how long current flows through the switch. In our example, state 1 and state 2 are each active 50% of the time. This is not always the case, but we assume it for the calculation for simplicity. The load current of 100A flows through switch S2 50% of the time. We speak of a “duty cycle” of DC = 0.5. This means the fraction of time during which current flows through one of the switches. In this example the saturation voltage is 2V. So the switch is an IGBT.
Efficiency
The losses of one switch are 150W. The two switches in the bridge have losses of 300W in total. A power of P = 100A ∙ 200V = 20kW is switched. We assume that the inductor is lossless. The following applies:
What is this good for? With this circuit we have achieved the best possible efficiency compared with all other solutions.
The parameters of the switches are responsible for the efficiency of the circuit. A switch with a higher saturation voltage in the closed state UCE,SAT leads to higher static losses. If the switching time is longer, the dynamic losses increase. These two parameters are decisive for the efficiency of the circuit.
The parameters current, voltage and switching frequency also influence the efficiency. Voltage and current are specified by the load; you have no control over them. The dynamic losses increase with the switching frequency. The switching frequency has many more effects in the circuit, which is why it is optimised in the overall system – taking the dynamic losses of the switches into account.
External links: Good source on this (in German)
Exercise
The losses in the switches of the following buck converter are to be calculated. We build the buck converter from an IGBT module, an input source and an inductor. We use two of the 6 switches of the IGBT module. You can find the data sheet of the IGBT module here. We integrate the IGBT module into the buck converter circuit as follows:

Source: data sheet of the IGBT module FS100R06KE3 from Infineon, page 7 top.
The IGBT module (lower part of the figure) is connected to the buck converter at three points (red), so that the left two of the 6 switches are used. The right 4 switches remain unused. So we need static and dynamic losses for one diode and one IGBT.
Parameters:
Use the following values for the exercise:
50% duty cycle
Input voltage 400V
Load current 100A
fSchalt = 10kHz.
The gate of the IGBT is driven with a control voltage of UGE = 15V to close it.
Ambient temperature Tvj = 25°C.
Always calculate with typical values.
Tasks
1. Determine the switching energy for switching on and off, EON and EOFF, for diode and IGBT from the data sheet. Note that the diode has almost no power loss when switching on, which is why this is not listed in the data sheet.
2. Calculate the dynamic losses of IGBT and diode.
3. Determine the saturation voltage of the IGBT and the forward voltage of the diode.
4. Calculate the static power loss of IGBT and diode.
Hints
The data sheet contains a lot that you can ignore for this exercise.
The first page describes the IGBT. The second page describes the diode.
You can take all values from the tables. You do not need the diagrams.