Power Electronics Switches
Switch parameters
Switches differ in the following parameters:Maximum voltage: The blocking voltage (switch in high-impedance state) is limited. If the voltage across an open switch exceeds its maximum value, the switch is immediately destroyed. It then either forms a permanent short circuit (R = 0Ω) or it is permanently open (R → ∞). A switch must withstand the output and input voltage of a circuit. Because of the switching transients (more on this later), a reserve of 50% is added to the highest voltage. Switches in an inverter in an electric car with a 400V battery therefore have a maximum blocking voltage of 600V (50% reserve).
Maximum current: The current between the switch terminals is limited. If the current exceeds its maximum value, the switch heats up too much. It is then destroyed within a few seconds. It then either forms a permanent short circuit (R = 0Ω) or it is permanently open (R → ∞).
Maximum power: The product of voltage and current at the switch is limited. The effect of too much power is similar to that of too much current.
Switching time: During switching, the resistance between the switch terminals changes within a defined time span. Good switches switch quickly, bad ones switch slowly. Within the switching time, the current in the switch changes within nanoseconds. The switching time depends on the drive circuit; the user can influence it somewhat. Switching on and switching off can take different amounts of time, so both switching times are specified separately.
Maximum switching frequency: The switch cannot be opened and closed again in arbitrarily quick succession. The maximum switching frequency indicates how often per second it can be opened and then closed again. The maximum frequency depends on the switching time. The minimum period of switching on and off is the turn-on time + turn-off time.
On-state behaviour: In the closed state, switches behave differently. One type of switch (MOSFET) has a small on-state resistance in the closed state, also called the on-resistance ROn. The greater the on-resistance, the greater the power loss in the switch while it conducts current. This is P = I2 ∙ ROn.
Another type of switch (IGBT) has an on-state voltage UCE,sat. The on-state voltage is also called the saturation voltage. It depends slightly on the current and lies in the range of 2..3V. The power loss in the “closed” state is then P = UCE,sat ∙ I. The power loss in the closed switch state is called static power loss.
Switching losses: At the moment of switching, switches have a very high power loss. We will clarify why later. Fortunately, a switching operation does not last long, so the time average of the switching losses is bearable. The more often switching takes place, the more problematic the switching losses become. The power loss during switching is called dynamic power loss.
Which switches we choose depends on the requirements of the application. In an electric car, a voltage of 400V with a current of several 100A has to be switched. In a drill, 18V and a few 10 amperes are switched. There are different kinds of switches for each of these.
Robust design: most power electronics circuits die from defective switches. They have to survive an extremely large number of switching cycles in their lifetime. So give all parameters some reserve, so that the switches are not permanently stressed at their load limit. Also take into account extreme operating conditions (e.g. great heat) and foreseeable fault conditions. Be gracious in the design of the switches, and the circuit will thank you with a longer service life.