Ripple

In power electronics we generate voltages and currents by switching fixed (DC) voltages onto inductors. As a result, the current in the inductor rises and falls around a mean value. This fluctuation is technically called “current ripple”. Many applications need a smooth current without much ripple. In an electrical machine, the torque (i.e. the force) is determined by the current. If the ripple of the current is high, we also get ripple in the force. An electrical machine therefore judders when the current ripple is high.

To minimise the ripple, we look at the equation for the current in the inductor. In the circuits considered so far, a DC voltage is always applied to the inductor. Depending on the switch position it has different values, but it is constant over time section by section. We simplify the integral under this assumption.

\[ \begin{gathered} \text{Voltage across the inductor: } U_L = U_{\mathrm{Ein}} - U_{\mathrm{Aus}} \text{ or } U_L = -U_{\mathrm{Aus}} \\[6pt] I_L(t) = I_{L0} + \frac{1}{L} \int U_L(t)\,dt \\[6pt] \text{Simplified integral: } I_L(t) = I_{L0} + \frac{U_L(t) \cdot \Delta t}{L} = I_{L0} + \Delta I \end{gathered} \]

The ripple is determined by the term ΔI in the current equation. It becomes smaller if we reduce the DC voltage in the numerator. However, this is often given by the application in the form of the source voltage. In practice this option is therefore ruled out.

The ripple also becomes smaller if the time Δt during which a voltage is applied to the inductor is reduced. This lever is used in practice. We always reduce the time during which a DC voltage is applied to the inductor to a minimum.

The inductance L of the inductor is in the denominator of the equation. A large inductor reduces the ripple, but also costs a lot of money and installation space. It is therefore often cheaper to reduce the times in the switch control. These times become smaller when the PWM frequency increases.

Download course as PDF

The PDF contains all pages of the course. Interactive content is only available on the website.